Estimated integrated loudness
--
Inspect local audio for sample peak, RMS, clipping, silence, channels and cautious delivery-readiness guidance with evidence you can export and review.
Free local audio evidence tool
Local audio evidence workspace
Choose an audio file to measure levels, clipping, silence, channels and delivery-readiness guidance locally.
Estimated integrated loudness
--
Sample peak
--
Clipping events
--
RMS level
--
Longest silence
--
Channel balance
--
A bounded peak envelope will be built from decoded samples.
Windowed RMS, sample peak, silence and events will appear here.
Evidence, guidance comparisons and human-review status appear after successful local decoding.
All audio decoding, waveform measurement, analysis and report generation run locally in your browser. Your audio file is not uploaded to MicroIntent, stored or modified.
Choose the file locally, inspect it, then compare the estimated integrated loudness and full-file RMS with your intended delivery guidance. The dashboard also preserves exact peak, clipping and silence evidence for human review.
Loudness estimates summarize sustained energy while sample peak is the largest decoded sample. A file can have a suitable estimated loudness yet have unsafe sample peaks, or the reverse, so both readings matter.
Clipping occurs when decoded samples reach the selected threshold. The tool groups adjacent or very close samples into evidence events, but it does not repair, normalize or alter source audio.
The inspector uses bounded RMS windows with editable threshold and minimum duration settings. It reports leading silence, trailing silence and internal gaps; intentional quiet passages still need a listener’s judgement.
Stereo delivery can sound unintentionally lopsided when left and right RMS differ substantially or one channel is silent. This tool reports evidence-based RMS balance, not a phase-correlation score.
Podcast speech and online video profiles provide editable production targets, peak limits and silence checks. They are starting points for a human workflow, not acceptance criteria for any platform.
Audiobook and broadcast-style profiles are cautious editable references. They do not certify Audible, ACX, ITU-R BS.1770, EBU R128, ATSC A/85 or any broadcaster requirement.
All decoding, analysis and report generation happen in your browser. The tool has no upload route, server action, remote DSP, microphone access, audio analytics or AI API.
Sample peak is measured from decoded audio samples and may not detect inter-sample peaks. True peak needs a validated reconstruction method, so this browser tool does not present one.
Crest factor is sample peak dBFS minus RMS dBFS. It is a simple dynamics indicator and is never presented as Loudness Range.
Clicks, noise, intent, edits, stereo imaging and context cannot be accepted automatically. Complete the in-tool listening checklist using headphones and ordinary speakers before deciding on delivery.
Estimated loudness and delivery comparisons are provided for production guidance. This version is not a certified broadcast-compliance meter. Results describe measurable properties of the decoded audio and do not guarantee acceptance by a receiving service.
Choose a local audio file, select Inspect, then review the estimated integrated loudness, RMS, sample peak, timeline and delivery comparison. The browser decodes and measures the file locally without uploading it.
LUFS is a loudness unit used by many delivery workflows. This tool labels its result Estimated integrated loudness because its browser-local estimator is not a certified standards-compliance measurement.
No. The estimator uses gated decoded-audio energy for production guidance but does not claim certified ITU-R BS.1770, EBU R128, ATSC A/85 or platform measurement compliance.
Sample peak is the largest decoded PCM sample. True peak estimates possible inter-sample peaks after reconstruction. This tool reports sample peak and explicitly does not claim true-peak measurement.
It finds decoded samples at or above the editable clipping threshold, groups adjacent or very close samples into events, and records each event's time, channel, count and maximum value.
Yes. It evaluates bounded RMS windows against editable silence and minimum-duration thresholds, then reports leading silence, trailing silence and internal long gaps. Quiet intentional sections can be classified as silence, so listening review remains necessary.
For stereo audio, it compares full-file left and right RMS, reports the difference and dominant channel, and flags silent or near-silent channels. It does not claim phase-correlation analysis.
Yes. It calculates the mean decoded sample value for each channel and flags values above the editable review threshold. DC offset is a measurable waveform bias and is not automatically audible.
The intake supports WAV, MP3, M4A, AAC, OGG and FLAC where the active browser can decode the codec. Extension and MIME declarations are checked, but successful local decoding is the final validation.
No. Audio decoding, waveform measurement, analysis and report generation run locally in the browser. The audio file is not uploaded, stored, modified or sent to an AI service.
Yes. Successful inspections can generate a print-ready Delivery readiness report, genuine Word DOCX, Markdown, JSON evidence, event CSV, finding CSV and a copied summary. Exports contain evidence, not raw PCM or audio contents.