Instrument Calibration Verification & Tolerance Checker

Verify up to five as-found and as-left calibration points against a fixed, percentage-of-reading or percentage-of-full-scale tolerance rule, with worked steps and a printable Calibration Verification Report. Runs locally in your browser.

Science & Engineering

Instrument Calibration Verification & Tolerance Checker

Enter as-found (and optional as-left) calibration readings against a declared tolerance rule to see point-level and overall pass/fail results.

Local calculationNo account requiredNo values uploaded

Instrument details

All values must use the same engineering unit. This tool does not convert between units.

Derived span:

Tolerance rule

Select the tolerance model

Calibration points

Enter up to five calibration points. Leave a row entirely blank to skip it.

Point 1

Point 2

Point 3

Point 4

Point 5

Results summary

Enter calibration details and press Calculate to see calibration results.

Point-level results

Enter calibration details and press Calculate to see point-level results.

Worked calculations

Enter calibration details and press Calculate to see the worked calculation.

Local processing

This tool runs entirely in your browser. It does not upload, store or transmit the values you enter.

Assumptions and limitations

This tool compares user-entered readings against a user-declared tolerance rule. It does not perform accredited calibration, establish metrological traceability, evaluate measurement uncertainty or replace a formal calibration certificate. It does not claim ISO/IEC 17025 compliance and does not certify equipment. It does not evaluate guard bands or false-accept/false-reject risk. It does not replace applicable procedures, standards or professional judgement. It does not determine suitability for safety-critical or regulated release. Each instrument uses a single declared engineering unit - no unit conversion is performed. Reference values are assumed to come from a suitable external standard or source. The tolerance rule (fixed units, percentage of reading, or percentage of full scale) is entirely user-supplied. Full scale means the declared instrument span (maximum minus minimum), not the maximum numerical value alone. Percentage-of-reading tolerance uses the absolute magnitude of the reference value and cannot be evaluated at a zero reference. Pass/fail results use only the entered reference, as-found and as-left values. Measurement uncertainty is not included in any calculation. Guard-banding is not included in any calculation. Environmental effects on the instrument or reference standard are not modelled. Drift between calibration events is not modelled. Hysteresis is not modelled. Repeatability is not modelled. Instrument resolution, digits and counts are not modelled. Results are informational and require independent verification before relying on them for safety-critical, regulated or contractual decisions.